Pump body and motor bracket in cast iron; shaft in stainless steel; impeller in noryl for Mod. CD 65/66/67; Impeller in stamped brass for Mod. CD 68/69/70/71/72;
Mechanical seal. Motor closed auto ventilated; Protection IP 44. Single-phase feeding 220 V - 50 Hz with incorporated motor protector, capacitor permanently connected.
Three-phase feeding 220/380 V - 50 Hz, protection to care of the user.
Mod. CD 65/66/67: max. Pressure 6 ate (88.8 P.S.I.); Water temperature; max. 50°C.
Mod. CD 68/69/70/71/72: max. Pressure 8 ate (118.4 P.S.I.); Water temperature: max. 90°C.
TYPE
Dimensions mm
Packing dimensions mm
Weight
A
B
C
D
E
F
H1
H2
DNA
DNM
I
L
M
kg
CD 65
95
44
265
150
110
160
82
202
1"G
1"G
290
175
225
9
CD 66
110
45
300
180
140
185
97
234
1"G
1"G
325
200
265
12.7
CD 67
110
45
300
180
140
185
97
234
1"G
1"G
325
200
265
14
CD 68
117
45
348
220
180
225
115
285
1"G
1"G
370
240
315
22.5
CD 69
117
45
348
220
180
225
115
285
1"G
1"G
370
240
315
23
CDt 70
117
45
348
220
180
225
115
285
1"G
1"G
370
240
315
23.5
CDt 71
108
58
425
240
190
250
133
323
1"G
1"G
440
270
360
39.8
CDt 72
108
58
425
240
190
250
133
323
1"G
1"G
440
270
360
39.8
TYPE
Nominal power
AMPERE
Single-phase
Three-phase
Single-phase
Three-phase
220 V - 50 Hz
220/380 V - 50 Hz
HP
KW
220 V
380 V
CD 65
CDt 65
0.5
0.37
3.1
1.0
CD 66
CDt 66
0.8
0.59
4.4
1.5
CD 67
CDt 67
1.0
0.74
6
2.2
CD 68
CDt 68
1.5
1.1
8.8
3.4
CD 69
CDt 69
2.2
1.65
12
3.9
CDt 70
3.0
2.2
4.7
CD 71
CDt 71
4
3.0
21
6.8
CDt 72
5.5
4.1
9.6
Q = capacity
m3/h 0.3
0.6
1.2
1.8
2.4
3
I/1' 5
10
20
30
40
50
Total head in meters w.c.
CD 65 | CDt 65
20.5
20
17.5
16
14
11
CD 66 | CDt 66
26.5
26
23.5
22
20
17.5
14
CD 67 | CDt 67
33
32.5
30.5
29.5
27.5
25
21
CD 68 | CDt 68
40.5
40
38
37
34.5
31
27.5
CD 69 | CDt 69
50.5
50
47.5
46
44.5
42
39
34
CDt 70
58.5
58
56
55
54
51
48
44
35
CD 71 | CDt 71
46
45
44
43
42
41
37.5
32.5
CDt 72
55
54.9
54.3
54
53
52
50
46
40
Performance specified refer to continuous operation, with a manometric suction lift of 7 m. and y=1 kg/dm3. For suction over 4 m. install a sucking pipe with internal diameter larger than the suction connection.