Pump body and motor bracket in cast iron; shaft in stainless steel; impeller in noryl for Mod. 2CD 67; Impeller in stamped brass for Mod. CD 68-al, 2CB 77; mechanical seal. Motor closed auto ventilated; Protection IP 44. Single-phase feeding 220 V - 50 Hz with incorporated motor protector, capacitor permanently connected. Three-phase feeding 220/380 V - 50 Hz, protection to care of the user.
Mod. 2CD 67: max. pressure 6 ate (88.8 P.S.I.); Water temperature: max. 50°C.
From mod. 2CD 68 to 2CB 77: max. pressure 10 ate (148 P.S.I.); Water temperature: max. 90°C.
TYPE
Dimensions mm
Packing dimensions mm
Weight
A
B
C
D
E
F
H1
H2
DNA
DNM
I
L
M
kg
TYPE
Nominal power
AMPERE
Capacity
Single-phase
Three-phase
Single-phase
Three-phase
220 V - 50 Hz
220/380 V - 50 Hz
HP
KW
220 V
380 V
Performance specified refer to continuous operation, with a manometric suction lift of 7 m. and y=1 kg/dm3. For suction over 4 m. install a sucking pipe with internal diameter larger than the suction connection.